469 research outputs found

    Standardised documentation of instrument use during laparoscopic surgery

    Get PDF
    Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich.This publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively.To date, usability problems for laparoscopic instruments have mainly been investigated using questionnaires or laboratory studies. However, this methodology prevents the duration and frequency of instrument use from being documented objectively. Therefore, a tablet was used to create a graphic user interface which enables instrument use by operating and assisting surgeons to be documented with a high level of temporal precision. In a preliminary study, instrument use was documented for five laparoscopic operations (0:44h-6:01h). 2021 actions and 221 changes of instruments were documented. The longest uninterrupted usage period without changing hands was determined for grasping forceps at 97 min

    Ein analytisches Modell für die Blutdruckübertragungsstrecke der invasiven Blutdruckmessung mit externer Flüssigkeitskopplung

    Get PDF
    Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich.This publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively.Die invasive Blutdruckmessung spielt in der Anästhesie und in der Intensivmedizin eine wichtige Rolle. Im klinischen Alltag wird vorwiegend das preisgünstige extrakorporale Blutdruckmeßverfahren mit einem externen Einwegtransducer eingesetzt. Die Qualität dieses Verfahrens hängt im wesentlichen von dem Druckübertragungsverhalten der Meßstrecke ab, welche hauptsächlich aus dem Katheter, den Verlängerungsschläuchen, der Flüssigkeitssäule und dem Transducer besteht. Zusätzlich beeinflussen in der Flüssigkeitssäule vorhandene Luftblasen die Druckübertragungsqualität. In diesem Beitrag wird eine analytische Methode zur Bestimmung der Übertragungseigenschaften dieses Blutdruckmeßsystems anhand eines erweiterten neuen Modell vorgestellt. In ihm sind alle wichtigen Bestandteile der Druckübertragungsstrecke hinsichtlich ihrer Geometrie und Materialeigenschaften berücksichtigt

    Untersuchung der zeitabhängigen Ballonaufweitung an PTCA-Kathetern

    Get PDF
    Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich.This publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively.Als ergänzende Komponente eines Prüfstandes für PTCA-Katheter (Herzkranzgefäßmodell, [1], [2]) wurde unter Verwendung eines Zweiachs-Lasermeßkopfes ODAC 15XY der Fa. Zumbach eine Durchmesserprüfvorrichtung für Katheterballons entwickelt. Mit ihr läßt sich ein wesentliches Kathetermerkmal, der einem definierten Innendruck zugeordnete Durchmesser des Ballons, untersuchen. Der Ballondurchmesser kann zur Beurteilung der Balloncompliance (dV/dp) herangezogen werden, weil die in die Volumenänderung weiterhin eingehende Längenänderung des Ballons für seine Anwendung im Koronargefäß nur eine untergeordnete Bedeutung besitzt. Eine Variation des verwendeten Inflationsdruckes innerhalb des zulässigen Bereichs ermöglicht es dem Anwender das Dilatationsergebnis an die Situation während der Intervention anzupassen. Zu diesem Zweck werden durch die Hersteller Tabellen mitgeliefert, die eine Zuordnung Ballondruck/Außendurchmesser vornehmen. Diese Darstellung trifft jedoch nur einen Teil des tatsächlichen Ballonverhaltens. Die verwendeten Kunststoffe ( PE, PET, oder PA) weisen während der Dilatation ein Kriechverhalten auf. Es führt dazu, daß bei konstantem Innendruck innerhalb der üblichen Dilatationszeit von 30s bis 60s der Ballondurchmesser langsam zunimmt. Ziel dieses Beitrages sind die Vorstellung des angewandten Untersuchungsverfahrens und der Nachweis einer Zeitabhängigkeit der erreichten Ballondurchmesser. Der Stichprobenumfang der bisher getesten Katheter läßt zur Zeit noch keine verallgemeinernden Schlüsse auf Unterschiede zwischen PTCA-Kathetertypen zu

    Reaktionskraftuntersuchungen bei Vorschub und Rückzug von PTCA-Kathetern in modellierten Koronargefäßen

    Get PDF
    Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich.This publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively.PTCA-Ballonkatheter werden zur Aufweitung von Verengungen der Herzkranzgefäße genutzt. Sie finden in verschiedenen Bauarten Anwendung. Zwischen diesen Kathetertypen und den Kathetern einer Bauart aber verschiedener Hersteller bestehen deutliche Differenzen in der Ausprägung anwendungsrelevanter Kathetermerkmale. In einem neuen Prüfstand für PTCA-Katheter werden der anatomische Aufbau (Lage, Durchmesser, Verzweigungen der Gefäße) und die Reibverhältnisse den physiologischen Verhältnissen nachgebildet. Möglich sind Messungen von Aktionskräften am Antrieb kombiniert mit Reaktionskraftmessungen in Modellgefäßen. Innerhalb dieses Beitrages werden Untersuchungen vorgestellt, die neben Abstützkräften des Katheters im Führungskatheter auch auf die Gefäßwand übertragene Kräfte bei Passage eines gekrümmten Gefäßabschnittes erfassen

    A mobile gait analysis system for optimization of prosthetic alignments

    Get PDF
    Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich.This publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively.The prosthesis alignment is of central importance for a harmonic gait, especially for upper limb amputees. Today alignment optimization is based on static measuring and the experience of the orthopaedic technician. To objectify the alignment process a mobile gait analysis system based on 10 inertial sensors and a 6 DOF force and moment sensor was developed at the TU Berlin. The dedicated software adds dynamic gait parameters into the optimization process and guides the necessary changes in the prosthesis alignment. Therefore 19 common alignment changes were analysed based on measurements with 2 subjects fitted with the C-Leg knee. The anterior and posterior displacement of the knee will be the focus of an additional study with 6 subjects

    Ein multifunktionales Herzkranzgefäßmodell: Nutzungsvarianten für vergleichende Untersuchungen an PTCA-Kathetern

    Get PDF
    Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich.This publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively.Obwohl neue koronarinterventionelle Techniken ihre Eignung für die minimalinvasive Therapie der koronaren Herzkrankheit unter speziellen Indikationsstellungen nachweisen konnten, ist die Ballondilatation (PTCA) bis heute das Standardverfahren zur Revaskularisierung verengter Koronargefäße. Das Verfahren belegt damit eine Mittelstellung zwischen medikamentöser Therapie und Bypassoperation. Der Erfolg der Operationstechnik liegt neben ihrer Einfachheit und des vergleichsweise geringen Bedarfs an Zubehör im wesentlichen darin begründet, daß allein bei der Ballondilatation kein die Flexibilität des Katheters einschränkender Zusammenhang zwischen Durchmesser des Anwendungsteiles und dem erzielbaren freien Lumen im Gefäß besteht. Die Kombinationsmöglichkeit der konventionellen PTCA mit der Applikation von Gefäßendoprothesen (Stents) sichert dem Verfahren eine zusätzliche Erweiterung seiner Anwendbarkeit

    Technically assisted rehabilitation

    Get PDF
    Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich.This publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively

    Softwarekomponenten zur Meßdatenverarbeitung für experimentelle Untersuchungen an PTCA-Kathetern

    Get PDF
    Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich.This publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively.Ein Prüfstand für Ballonkatheter (Herzkranzgefäßmodell) ist den anatomischen Verhältnissen nachempfunden. Meßbar sind Aktions- und Reaktionskräfte an verschiedenen Positionen ebenso wie Drücke im Ballon und in Modellstenosen. Nachdem der grundlegende Aufbau der Meßdatenerfassung und Ansteuerung aktiver Prüfstandkomponenten ebenso wie ein Fuzzy-Bewertungsprogramm bereits vorgestellt wurden, liegen die Schwerpunkte dieses Beitrages auf der Beschreibung der zur Datenerfassung und Datenaufbereitung entwickelten Software

    A novel method for patient-oriented assignment of wheelchair cushions based on standardized laboratory testing procedures

    Get PDF
    Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich.This publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively.Rollstuhlsitzkissen sind die Schnittstelle zwischen Rollstuhl und Rollstuhlfahrer und übernehmen dabei Last übertragende und stabilisierende Aufgaben. Zusätzlich sollen sie helfen, Druckgeschwüre durch mechanische Entlastung und einen Abtransport von Feuchtigkeit und Wärme zu vermeiden. Die Auswahl eines Sitzkissen erfolgt dabei häufig anhand einer subjektiven Einschätzung der Sitzkisseneigenschaften, was die durchschnittliche Qualität der Versorgung negativ beeinflussen kann und unter Kostengesichtspunkten die Auswahl hochwirksamer Kissen nur schwer rechtfertigt. Dieser Artikel beschreibt ein Verfahren, Sitzkissen anhand von messtechnisch erfassten Kennwerten und einer standardisierten Patientenprofilerhebung auszuwählen. Dazu wird eine Übersicht über die am Markt erhältlichen Sitzkissen gegeben und Möglichkeiten erörtert, die Sitzkissen anhand von strukturierten Entscheidungshilfen nachvollziehbar auszuwählen und die Anforderungen des Patienten unterstützend einzuteilen und zuzuordnen.A wheelchair seat cushion represents the interface between the wheelchair and the wheelchair driver and has to manage the force transmission and the stabilization between both of them. An additional very important requirement is the prevention of pressure ulcers by pressure relief and the transfer of humidity and heat away from the patient. The allocation of a cushion to the patient happens normally on the base of a subjective description of the cushion without any transparent decision rules. Consequently the quality of this procedure could be improved by a better description of the cushion, based on standardized laboratory tests and by the development of decision tools helping to identify the main efforts of the user. This article describes a procedure that allows the allocation of wheelchair seat cushions based on the characteristic of cushions from standardized laboratory tests and on the brief description of the user. Additionally the existing principles for wheelchair cushions are listed, described and compared. The possibilities to develop structured decision tools for wheelchair cushions are discussed
    corecore